AC220V is the standard mains voltage of many countries and regions in the world (such as China, Europe, etc.), widely used in the following scenarios, such as household appliances such as air conditioners, refrigerators, washing machines, televisions, industrial equipment such as motors, PLC controllers, frequency inverters, imaging equipment (such as CT, MRI), life support systems (such as ventilators) and other medical equipment. For communication infrastructure such as base stations, servers, and switches, lightning strikes or power grid surges may cause short circuit damage or even fire in AC220V applications. Through reasonable protection design can significantly improve the reliability of devices under extreme conditions such as lightning strikes to ensure long-term and stable operation of the system.
IEC 61000-4-5、GB/T 17626.5、EN61000-4-5
1, The front-end fuse provides protection against circuit overload, short circuits;
2, The cost-effective solution using conventional parallel varistor between L-N differential mode;
3, The common mode L/N line respectively uses a varistor and then connected in series with a ceramic gas discharge tube to PE to provide a surge discharge path;
4, The power NTC connected in series on the N-line effectively suppresses inrush current during power-on;
5, To meet the insulation withstand voltage test of the input to the ground, need to adjust the voltage parameters of the GDT.
▲The solution for reference only, if you need a detailed design scheme or customization according to your protection level requirements, please feel free to contact us, we will provide professional technical support and solutions based on your specific needs.

| Part Number | Package | Number of poles |
Spark-over Voltage @100V/S DC(V) |
Impulse Spark-over Voltage @100V/µS |
Impulse Spark-over Voltage @1KV/µS |
Minmum Insulation Resistance (MΩ) |
Arc Voltage @1A (V) |
Surge Current 8/20µs (A) |
Cj @1MHz (pF) |
Datasheet |
|---|
| Part Number | Package | Maximum Allowable Voltage Vac(V) |
Maximum Allowable Voltage Vdc(V) |
Varistor Voltage @1mA (V) |
Max Peak Current@ 8/20µs |
Number of lighting @Max Peak Current 8/20µs |
Max Clamping Voltage@Ip Vc(V) |
Maximum Energy (10/1000µs) (J) |
Datasheet |
|---|
| Part Number | Package | Type | VDS (V) |
VGS (V) |
VTH (MIN) (V) |
VTH (MAX) (V) |
ID @25°C (A) |
RDS(ON) @VGS=10V Typ(mΩ) |
RDS(ON) @VGS=10V Max(mΩ) |
RDS(ON) @VGS=4.5V Typ.(mΩ) |
RDS(ON) @VGS=4.5V Max(mΩ) |
ESD | AEC-Q101 | Datasheet |
|---|
| Part Number | Package | Fusing characteristics | Body Material | Rated Current (A) | Rated Voltage | Resistance (mΩ) | Nominal Melting I2T (A2sec) | Datasheet |
|---|
| Part Number | Package | Max. Average Rectified Current IF (A) |
Max. Peak Reverse Voltage VRRM (V) |
Max.Peak Forward Surge Current IFSM (A) |
Max. Forward Voltage VF@IF (V) |
Max. Reverse Current IR@VRRM(mA) |
Datasheet |
|---|
| Part Number | Package | Maximum Power Dissipation PD (mW) |
Max. Average Rectified Current IF (A) |
Peak Repetitive Reverse Voltage VRRM (V) |
Max.Peak Forward Surge Current IFSM (A) |
Max. Forward Voltage VF@IF (V) |
Max. Reverse Current IR@VRRM(mA) |
AEC-Q101 | Datasheet |
|---|
| Part Number | Package | Rated resistance R25 (Ω) |
Max. steady State current (A) |
Residusl Resistance (Ω) |
Max. allowable capacity value 240V/120V (μF) |
Operating Temperature (°C) |
Datasheet |
|---|